Fatek Winproladder



1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Low skill level to exploit
  • Vendor: FATEK Automation
  • Equipment: PLC WinProladder
  • Vulnerability: Stack-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of this vulnerability could crash the device being accessed; a buffer overflow condition may cause a denial-of-service event and remote code execution.

3. TECHNICAL DETAILS

Download Software FATEK Programming Software File Name Version File Size Note Download WinProladder V3.28 3.06 MB For FBs/B1/B1z WinProladder USER-Manual (PDF) 8.15 MB User-Manual PDF Modules Manual 6.01 MB All Modules Manuals FBs – 30GM File Name Version File Size Note Download dataftpPLC 66.2 MB dataftpPLC USER-Manual (PDF) 4.45 MB User-Manual PDF OS. FATEK Automation Corp. Was established in 1992 in Taiwan by a group of engineers engaged in PLC design and development for many years. Since its establishment, FATEK has strived for R&D in order to provide high-quality, high-function and user-friendly automatic control products. The product line focuses on PLC, HMI, IoT solutions, SCADA application software, OPC Server and power supply, etc.

3.1 AFFECTED PRODUCTS

The following versions of PLC WinProladder are affected:

  • PLC WinProladder Version 3.28 and prior

3.2 VULNERABILITY OVERVIEW

3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121

A stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code.

CVE-2020-16234 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

Winproladder Software Fatek

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Commercial Facilities
  • COUNTRIES/AREAS DEPLOYED: Europe, Asia
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Natnael Samson (@NattiSamson), working with Trend Micro’s Zero Day Initiative, reported this vulnerability to CISA.

4. MITIGATIONS

FATEK has not responded to requests to work with CISA to mitigate this vulnerability. Users of these affected products who would like to see more responsible security are invited to contact Fatek customer support.

CISA recommends users take the following measures to protect themselves from social engineering attacks:

  • Do not click web links or open unsolicited attachments in email messages.
  • Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
  • Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

Fatek Winproladder

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.

Winproladder

Source:

Software Download

Software NameVersionSizeUpdatedTypeDownload
FBs-PLC USB Port Driver (U2C-FT230) For All Windowsv2.12.161.29MB2016-06-03URL
FBs-30GM default parameters(for FBs-30GM Program_Block V1.1 V1.2)1KB2014-05-29URL
QCU18 software for FBs-CMZBR3.60MB2014-09-17URL
Facon Server for Win8693KB2013-09-06URL
FBs-PLC Server USB Port Driver For Win8 & Win8.13.93MB2014-06-10URL
Winproladder for DOS2013-02-25URL
CBEH manual2012-12-06URL
Service Call CenterV1.0 build 201109142012-11-27URL
EasyWebDesignerV1.1 Build 201503171.75MB2015-03-18URL
CANopen Communication Board User’s Manual2012-12-06URL

Fatek Plc Winproladder

Software NameVersionSizeUpdatedType
EasyCANopenerV1.0 Build 201205092012-11-27URL
PEPD SoftwareV1.2 build 031520112012-12-06URL
Vom Edit SoftWareV1.01 build 020220102012-12-06URL
FBs-PLC Server USB Port Driver For W72012-11-27URL
FBs-PLC Server USB Port Driver For VISTA2012-11-27URL
FBs-PLC Server USB Port Driver For WinXP2013-01-24URL
FATEK Communication Server ToolsV1.13-147212012-12-06URL
OS update guide2012-12-06URL
FP-08 OS FileV1.082012-12-06URL
FP-08 OS Update(PP Boot.exe) ToolsV1.012012-12-06URL
Software NameVersionSizeUpdatedType
Ethernet module Configuration Set and USER-Manual2013-01-24URL
Ethernet Module Configure ToolsV3.3 build20131112666KB2013-11-12URL
OS version change noteV4.79156KB2016-01-04URL
FBs-30GM default parameters(for FBs-30GM Program_Block V1.4)1KB2016-10-28URL
GMMon (FBs-30GM software)V1_04_01_1512P18.79MB2015-04-20URL
OS Version VariationV4.03~V4.792.3MB2016-01-04URL
WinProladderChangeNoteWinProladder V3.25 ChangeNote2016-05-16URL
WinProladderV3.25 Build 193273.06MB2016-08-03URL
FBs-30GM OS fileV10.116.8.165.81MB2015-04-29URL
OS update guide2013-01-24URL
Software NameVersionSizeUpdatedType
WinProladderV3.25 Build 191183.11MB2016-05-23URL
FBs-30GM Program_Block_and_IO_Plugin V1.1V1.18.49KB2015-04-20URL
OS Update ToolsV1.612014-08-12URL
FBs OS FileV4.79208KB2016-01-04URL
FBs-30GM Program_Block_and_IO_Plugin V1.2V1.219.5KB2015-04-20URL
WinProladderV3.24 Build 177053.09MB2014-08-20URL
FBs OS FileV4.78208KB2015-09-08URL
FBs-30GM Program_Block_and_IO_Plugin V1.4V1.420.9KB2016-10-28URL
WinProladderV3.23 Build 17205-13.09MB2014-03-28URL
FBs OS FileV4.77208KB2015-05-05URL
Software NameVersionSizeUpdatedType
WinProladderV3.22 Build 166303.03MB2013-11-25URL
FBs-30GM Change Start Position Function5.25KB2015-11-12URL
FBs OS FileV4.76208KB2015-01-13URL
WinProladderV3.21 Build 160012013-04-01URL
FBs OS FileV4.68208KB2015-05-05URL
WinProladderV3.20 Build 15428-32012-12-06URL
WinProladderV3.11 Build 147012014-01-16URL

FATEK PLC SOFTWARE, FATEK PLC SUPPLIERS DEALERS IN MAHARASHTRA NASHIK INDIA, PLC SUPPLIERS